Q1. Which term defines the closeness of agreement between a measured value and the true or reference value of an analyte?
A) Accuracy
B) Precision
C) Reliability
D) Specificity
Q1. рдорд╛рдкреЗ рдЧрдП рдорд╛рди рдФрд░ рд╡рд┐рд╢реНрд▓реЗрд╖реНрдп рдХреЗ рд╡рд╛рд╕реНрддрд╡рд┐рдХ рдпрд╛ рд╕рдВрджрд░реНрдн рдорд╛рди рдХреЗ рдмреАрдЪ рдХреА рдирд┐рдХрдЯрддрд╛ рдХреЛ рдХреНрдпрд╛ рдХрд╣рд╛ рдЬрд╛рддрд╛ рд╣реИ?
A) рдпрдерд╛рд░реНрдерддрд╛ (Accuracy)
B) рдкрд░рд┐рд╢реБрджреНрдзрддрд╛ (Precision)
C) рд╡рд┐рд╢реНрд╡рд╕рдиреАрдпрддрд╛ (Reliability)
D) рд╡рд┐рд╢рд┐рд╖реНрдЯрддрд╛ (Specificity)
Answer: (A)
Accuracy refers to the closeness of a measured result to the true or accepted reference value. Precision refers to repeatability.
рдпрдерд╛рд░реНрдерддрд╛ (Accuracy) рдХрд┐рд╕реА рдкрд░реАрдХреНрд╖рдг рдорд╛рди рдХреА рдЙрд╕рдХреЗ рд╡рд╛рд╕реНрддрд╡рд┐рдХ рдпрд╛ рд╕реНрд╡реАрдХреГрдд рд╕рдВрджрд░реНрдн рдорд╛рди рд╕реЗ рдирд┐рдХрдЯрддрд╛ рдХреЛ рджрд░реНрд╢рд╛рддреА рд╣реИред [рд╕реНрд░реЛрдд: рдбреЙ. рдкреНрд░рдлреБрд▓ рдмреА. рдЧреЛрдбрдХрд░ - рдореЗрдбрд┐рдХрд▓ рд▓реЗрдмреЛрд░реЗрдЯрд░реА рдЯреЗрдХреНрдиреЛрд▓реЙрдЬреА]
Q2. What is the statistical formula used to calculate the Coefficient of Variation (CV%) in laboratory quality control?
A) CV% = (Mean / SD) x 100
B) CV% = (Standard Deviation / Mean) x 100
C) CV% = (Variance / Mean) x 100
D) CV% = (Mean / Variance) x 100
Q2. рдкреНрд░рдпреЛрдЧрд╢рд╛рд▓рд╛ рдЧреБрдгрд╡рддреНрддрд╛ рдирд┐рдпрдВрддреНрд░рдг рдореЗрдВ рд╡рд┐рдЪрд░рдг рдЧреБрдгрд╛рдВрдХ (CV%) рдХреА рдЧрдгрдирд╛ рдХрд░рдиреЗ рдХреЗ рд▓рд┐рдП рдХрд┐рд╕ рд╕реВрддреНрд░ рдХрд╛ рдЙрдкрдпреЛрдЧ рдХрд┐рдпрд╛ рдЬрд╛рддрд╛ рд╣реИ?
A) CV% = (рдорд╛рдзреНрдп / SD) ├Ч 100
B) CV% = (рдорд╛рдирдХ рд╡рд┐рдЪрд▓рди / рдорд╛рдзреНрдп) ├Ч 100
C) CV% = (рдкреНрд░рд╕рд░рдг / рдорд╛рдзреНрдп) ├Ч 100
D) CV% = (рдорд╛рдзреНрдп / рдкреНрд░рд╕рд░рдг) ├Ч 100
Answer: (B)
The Coefficient of Variation (CV%) expresses standard deviation as a percentage of the mean: CV% = (SD / Mean) x 100. Lower CV% indicates superior analytical precision.
рд╡рд┐рдЪрд░рдг рдЧреБрдгрд╛рдВрдХ (CV%) рдХрд╛ рд╕реВрддреНрд░ CV% = (рдорд╛рдирдХ рд╡рд┐рдЪрд▓рди / рдорд╛рдзреНрдп) ├Ч 100 рд╣реЛрддрд╛ рд╣реИред рдХрдо CV% рдЙрдЪреНрдЪ рдкрд░рд┐рд╢реБрджреНрдзрддрд╛ рдХреЛ рджрд░реНрд╢рд╛рддрд╛ рд╣реИред [рд╕реНрд░реЛрдд: рдЯрд┐рдЯреНрдЬрд╝ рдХреНрд▓рд┐рдирд┐рдХрд▓ рдХреЗрдорд┐рд╕реНрдЯреНрд░реА]
Q3. In a Gaussian distribution, what percentage of control values falls within the range of Mean ┬▒ 2 Standard Deviations (┬▒2 SD)?
A) 68.2%
B) 90.0%
C) 95.5%
D) 99.7%
Q3. рд╕рд╛рдорд╛рдиреНрдп рдЧреЙрд╕рд┐рдпрди рд╡рд┐рддрд░рдг рдореЗрдВ, рдХрд┐рддрдиреЗ рдкреНрд░рддрд┐рд╢рдд рдирд┐рдпрдВрддреНрд░рдг рдорд╛рди рдорд╛рдзреНрдп ┬▒ 2 рдорд╛рдирдХ рд╡рд┐рдЪрд▓рди (┬▒2 SD) рдХреА рд╕реАрдорд╛ рдХреЗ рднреАрддрд░ рдЖрддреЗ рд╣реИрдВ?
A) 68.2%
B) 90.0%
C) 95.5%
D) 99.7%
Answer: (C)
In a normal Gaussian curve, approximately 68.2% of values fall within ┬▒1 SD, 95.5% within ┬▒2 SD, and 99.7% within ┬▒3 SD of the mean.
рд╕рд╛рдорд╛рдиреНрдп рдЧреЙрд╕рд┐рдпрди рд╡рд┐рддрд░рдг рдореЗрдВ 68.2% рдорд╛рди ┬▒1 SD рдХреЗ рднреАрддрд░, 95.5% рдорд╛рди ┬▒2 SD рдХреЗ рднреАрддрд░, рдФрд░ 99.7% рдорд╛рди ┬▒3 SD рдХреЗ рднреАрддрд░ рдЖрддреЗ рд╣реИрдВред [рд╕реНрд░реЛрдд: рдбреЙ. рдкреНрд░рдлреБрд▓ рдмреА. рдЧреЛрдбрдХрд░ - рдореЗрдбрд┐рдХрд▓ рд▓реЗрдмреЛрд░реЗрдЯрд░реА рдЯреЗрдХреНрдиреЛрд▓реЙрдЬреА]
Q4. What statistical line represents the center of a clinical laboratory Levey-Jennings (L-J) control chart?
A) Median
B) Mode
C) Variance
D) Target Mean
Q4. рдХреНрд▓рд┐рдирд┐рдХрд▓ рдкреНрд░рдпреЛрдЧрд╢рд╛рд▓рд╛ рдХреЗ рд▓реЗрд╡реЗ-рдЬреЗрдирд┐рдВрдЧреНрд╕ (L-J) рдХрдВрдЯреНрд░реЛрд▓ рдЪрд╛рд░реНрдЯ рдХреЗ рдХреЗрдВрджреНрд░ рдореЗрдВ рдХреМрди рд╕реА рд╕рд╛рдВрдЦреНрдпрд┐рдХреАрдп рд░реЗрдЦрд╛ рд╣реЛрддреА рд╣реИ?
A) рдорд╛рдзреНрдпрд┐рдХрд╛ (Median)
B) рдмрд╣реБрд▓рдХ (Mode)
C) рдкреНрд░рд╕рд░рдг (Variance)
D) рд▓рдХреНрд╖рд┐рдд рдорд╛рдзреНрдп (Target Mean)
Answer: (D)
The central horizontal baseline of a Levey-Jennings chart represents the target mean value of the control material, with parallel lines at ┬▒1, ┬▒2, and ┬▒3 SD.
рд▓реЗрд╡реЗ-рдЬреЗрдирд┐рдВрдЧреНрд╕ рдЪрд╛рд░реНрдЯ рдХреА рдХреЗрдВрджреНрд░реАрдп рдХреНрд╖реИрддрд┐рдЬ рд░реЗрдЦрд╛ рдирд┐рдпрдВрддреНрд░рдг рд╕рд╛рдордЧреНрд░реА рдХреЗ рд▓рдХреНрд╖рд┐рдд рдорд╛рдзреНрдп (Target Mean) рдХреЛ рджрд░реНрд╢рд╛рддреА рд╣реИред [рд╕реНрд░реЛрдд: рдбреЙ. рдкреНрд░рдлреБрд▓ рдмреА. рдЧреЛрдбрдХрд░ - рдореЗрдбрд┐рдХрд▓ рд▓реЗрдмреЛрд░реЗрдЯрд░реА рдЯреЗрдХреНрдиреЛрд▓реЙрдЬреА]
Q5. Under standard Westgard multirule protocols, which rule is defined as a warning rule that alerts the technologist to inspect analytical data?
A) 1_2s rule
B) 1_3s rule
C) 2_2s rule
D) R_4s rule
Q5. рдорд╛рдирдХ рд╡реЗрд╕реНрдЯрдЧрд╛рд░реНрдб рдмрд╣реБ-рдирд┐рдпрдореЛрдВ рдХреЗ рддрд╣рдд, рдХрд┐рд╕ рдирд┐рдпрдо рдХреЛ рдЪреЗрддрд╛рд╡рдиреА рдирд┐рдпрдо (Warning rule) рдХреЗ рд░реВрдк рдореЗрдВ рдкрд░рд┐рднрд╛рд╖рд┐рдд рдХрд┐рдпрд╛ рдЧрдпрд╛ рд╣реИ?
A) 1_2s рдирд┐рдпрдо
B) 1_3s рдирд┐рдпрдо
C) 2_2s рдирд┐рдпрдо
D) R_4s рдирд┐рдпрдо
Answer: (A)
The 1_2s rule is triggered when one control observation exceeds ┬▒2 SD. It is conventionally treated as a warning rule, prompting closer review of the run.
1_2s рдирд┐рдпрдо рддрдм рд▓рд╛рдЧреВ рд╣реЛрддрд╛ рд╣реИ рдЬрдм рдХреЛрдИ рдПрдХ рдирд┐рдпрдВрддреНрд░рдг рдорд╛рди ┬▒2 SD рд╕реЗ рдмрд╛рд╣рд░ рдЬрд╛рддрд╛ рд╣реИред рдпрд╣ рдЪреЗрддрд╛рд╡рдиреА рдирд┐рдпрдо рд╣реИ рдЬреЛ рдбреЗрдЯрд╛ рдХреА рд╕рдореАрдХреНрд╖рд╛ рдХрд╛ рд╕рдВрдХреЗрдд рджреЗрддрд╛ рд╣реИред [рд╕реНрд░реЛрдд: рдбреЙ. рдкреНрд░рдлреБрд▓ рдмреА. рдЧреЛрдбрдХрд░ - рдПрдордПрд▓рдЯреА]
Q6. Which Westgard multi-rule violation indicates a run rejection caused by acute random error when a single control exceeds ┬▒3 SD?
A) 1_2s rule
B) 1_3s rule
C) 4_1s rule
D) 10_x rule
Q6. рдЬрдм рдПрдХ рдПрдХрд▓ рдирд┐рдпрдВрддреНрд░рдг рдорд╛рди ┬▒3 SD рд╕реЗ рдмрд╛рд╣рд░ рдЪрд▓рд╛ рдЬрд╛рддрд╛ рд╣реИ, рддреЛ рдХреМрди рд╕рд╛ рд╡реЗрд╕реНрдЯрдЧрд╛рд░реНрдб рдирд┐рдпрдо рддреАрд╡реНрд░ рдпрд╛рджреГрдЪреНрдЫрд┐рдХ рддреНрд░реБрдЯрд┐ (Random error) рдХреЗ рдХрд╛рд░рдг рд░рди рдХреЛ рдЕрд╕реНрд╡реАрдХрд╛рд░ рдХрд░рддрд╛ рд╣реИ?
A) 1_2s рдирд┐рдпрдо
B) 1_3s рдирд┐рдпрдо
C) 4_1s рдирд┐рдпрдо
D) 10_x рдирд┐рдпрдо
Answer: (B)
The 1_3s rule is a mandatory run-rejection rule triggered when a single control value exceeds ┬▒3 SD, primarily sensitive to acute random error.
1_3s рдирд┐рдпрдо рддрдм рд▓рд╛рдЧреВ рд╣реЛрддрд╛ рд╣реИ рдЬрдм рдПрдХ рдирд┐рдпрдВрддреНрд░рдг рдорд╛рди ┬▒3 SD рд╕реЗ рдмрд╛рд╣рд░ рдирд┐рдХрд▓ рдЬрд╛рддрд╛ рд╣реИред рдпрд╣ рдпрд╛рджреГрдЪреНрдЫрд┐рдХ рддреНрд░реБрдЯрд┐ (random error) рдХреЗ рдХрд╛рд░рдг рдкрд░реАрдХреНрд╖рдг рд░рди рдЕрд╕реНрд╡реАрдХрд╛рд░ рдХрд░рдиреЗ рдХрд╛ рдирд┐рдпрдо рд╣реИред [рд╕реНрд░реЛрдд: рдЯрд┐рдЯреНрдЬрд╝ рдХреНрд▓рд┐рдирд┐рдХрд▓ рдХреЗрдорд┐рд╕реНрдЯреНрд░реА]
ЁЯФТ

Unlock Full Document

Get instant access to all questions, solutions, and PDF download.

How to Download RRB LA UT07 – Quality Assurance & QC Practice Test (IQC, EQAS, Westgard Rules) PDF?

  1. This is a Premium PDF. You need to unlock it first.
  2. Choose a suitable plan from the options above.
  3. Once unlocked, the download button will become active immediately without any ads.

ЁЯдЦ Practice Daily on Telegram

Join thousands of students taking daily free quizzes.

Open @solotutesPracticeBot

What You Will Get in RRB LA UT07 – Quality Assurance & QC Practice Test (IQC, EQAS, Westgard Rules) PDF?

  • тЬФ A high-quality PDF of RRB LA UT07 – Quality Assurance & QC Practice Test (IQC, EQAS, Westgard Rules) with proper formatting
  • тЬФ Easy to read offline on mobile, tablet, or desktop
  • тЬФ Great for revision, practice, and quick reference
  • тЬФ Additional learning support with related videos and resources linked on this page
  • тЬФ Supports our mission: тАЬKnowledge for EveryoneтАЭ

Why Choose Solotutes?

At Solotutes, we provide access to notes, quizzes, MCQs, one-liners, and tests for multiple exams. By downloading RRB LA UT07 – Quality Assurance & QC Practice Test (IQC, EQAS, Westgard Rules) in PDF format, you not only get valuable material but also become part of a growing community of learners. We regularly update our posts with videos, explanations, and extra content to help you understand topics better.

FAQs тАУ RRB LA UT07 – Quality Assurance & QC Practice Test (IQC, EQAS, Westgard Rules) Download

Q. Is this PDF really free?
тЬЕ Yes! Free resources are completely free. Premium resources require a one-time unlock or pass.

Q. Do I need to sign up?
тЭМ For free PDFs, no account is needed. For premium tests, login is required to verify your purchase.

Q. Can I share this PDF with my friends?
тЬФ Yes, please share and help others learn too.

About Solotutes

Solotutes.com is dedicated to students preparing for competitive exams, schools, and universities. We provide free PDFs, quizzes, MCQs, notes, and one-liners to make learning easy and accessible.

ЁЯСС Tired of Waiting and Ads? Go PRO!

Upgrade to the SoloTutes Pro Pass and supercharge your exam preparation.

  • ЁЯЪл Ad-Free Experience: Say goodbye to ads and 1-minute waiting timers.
  • ЁЯУЭ Custom PDF Generator: Build your own exam/subject-wise PDFs.
  • ЁЯУЪ PDF Library: Access 1000+ question eBooks.
  • ЁЯФУ Unlock Test Series: Get access to all current and upcoming paid test series.
Get Pro Pass for тВ╣249/yr
Scroll to Top